INDUSTRUIES

0.6/1 KV 4*50mm2 XLPE insulation PVC sheath power cable

Place of Origin:Hebei, China (Mainland)       Brand Name:Prisaman
Model Number:YJV                                       Insulation Material:XLPE
Type:Low Voltage                                            Application:Underground
Conductor Material:Copper                              Jacket:PVC
Product name:xlpe pvc cable
Certificate:ISO9001/ISO14001 /OHSAS18001/CCC
Conductor:Copper                                                Insulation:XLPE
Rated voltage:0.6/1KV                                       Standard:IEC60502-1
Sheath:PVC                                                          Core:1-5 core
Color:Black,red ,yellow….                               Delivery:As per order

1 Product Standard

This product is manufactured according to GB/T12706.1, equivalent to IEC60502.1. Or BS, DIN, ICEA standard as customer request.  

 2 Application

The product is suitable for power transmission and distribution lines with rated power frequency voltage up to and including 0.6/1KV.

Operating Performance

1). Rated power frequency voltage Uo/U: 0.6/1KV.
2). Max. Permissible continuous operating temperature of conductor: 90℃
3). Max. Short-circuit temperature of the conductor shall not exceed: (5S maximum duration) 250℃

4). The ambient temperature under installation should not below 0℃
5). The bending radius of a cable should not be less than 15 times of the cable diameter.

6). The test voltage (A.C.): 3.5kV/5min.

7). The flame-retardant properties of cable comply with grade A, B, C of GB/T19666-2005 or IEC60332.

 3 Construction:

 

Conductor: Solid or stranded copper,aluminum

 

Insulation: Cross-linked polyethylene( XLPE or PVC)

Circuit Identification: The insulation shall be red, black

Filler: Polypropylene lament with lapped binding tape

Inner Sheath: Polyvinyl chloride (Black)

Armor: Galvanized steel wire

Core-covering: Binding tape

Outer Sheath: Polyvinyl chloride (Black)

 

Package:  Wooden Drum Package or Iron-wooden drum 

Type and name:

 

Type

Designation

Applications

YJV Copper conductor,XLPE insulated,PVC sheathed power cable For laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.
YJLV Aluminum conductor,XLPE insulated,PVC sheathed power cable
YJY Copper conductor, XLPE insulated,PE sheathed power cable
YJLY Aluminum conductor, XLPE insulated,PE sheathed power cable
YJV22 Copper conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable For laying indoors,in tunnel in cable trench,or direct in ground,able to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.
YJLV22 Aluminum conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable
YJV23 Copper conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJLV23 Aluminum conductor,XLPE insulated,steel tape armoured,PE sheathed power cable
YJV32 Copper conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force.
YJLV32 Aluminum conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable
YJV33 Copper conductor,XLPE insulated,steel wire armoured,PE sheathed power cable
YJLV33 Aluminum conductor,XLPE insulated,steel wire armoured,PE sheathed power cable

Type

No. of cores

Nom. Cross-section of conductor

(mm2)

Copper conductor

Aluminum conductor

YJV  YJY

1

1.5-800

YJLV  YJLY

2.5-800

YJV22  YJV23 YJLV22  YJLY23

10-800

YJV  YJY

2

1.5-300

YJLV  YJLY

2.5-300

YJV22  YJV23 YJLV22  YJLY23

4.0-300

YJV32  YJV33 YJLV32  YJLY33

10-300

YJV  YJY

3

1.5-400

YJLV  YJLY

2.5-400

YJV22  YJV23 YJLV22  YJLY23

4.0-400

YJV32  YJV33 YJLV32  YJLY33

10-400

YJV  YJY

4

1.5-400

YJLV YJLY

2.5-400

YJV22  YJV23 YJLV22  YJLY23

4.0-400

YJV32  YJV33 YJLV32  YJLY33

10-400

YJV  YJY

3+1

1.5-400

YJLV  YJLY

4.0-400

YJV22  YJV23 YJLV22  YJLY23

4. 0-400

YJV32  YJV33 YJLV32  YJLY33

10-400

YJV  YJY

5

1.5-400

YJLV  YJLY

2.5-400

YJV22  YJV23 YJLV22  YJLY23

4.0-400

YJV32  YJV33 YJLV32  YJLY33

10-400

YJV  YJY

4+1

1.5-400

YJLV  YJLY

4.0-400

YJV22  YJV23 YJLV22  YJLY23

4. 0-400

YJV32  YJV33 YJLV32  YJLY33

10-400

YJV  YJY

3+2

1.5-400

YJLV  YJLY

4.0-400

YJV22  YJV23 YJLV22  YJLY23

4. 0-400

YJV32  YJV33 YJLV32  YJLY33

10-400

The armoured single core cables are used for D.C. system only. As for A.C. system,non-magnetic armour material should be used, or a magnetic isolation should be applied.